25.35
InForm OS Version 2.2.4 Command Line Interface Reference
–filt <fspec>
Specifies that statistics that fall below the threshold as specified by the <fspec>
arguments where <fspec> is <type>, <op>, <meas>, <val>, are filtered out and not
displayed. The
–filt option applies to data transfers only. The type, operation, meas,
and value arguments are separated with one comma.
<type>
The type argument can be specified with one of the following arguments:
curs
Specifies that only current statistics are displayed.
avgs
Specifies that only averages are displayed.
maxs
Specifies that only statics for maximum values are displayed.
<op>
The operation argument can be specified with one of the following arguments:
r
Specifies that read-only statistics are displayed.
w
Specifies that write-only statistics are displayed.
t|rw
Specifies that statistics for read and write totals are displayed.
<meas>
The meas argument can be specified with one of the following arguments:
iops
Specifies that I/O operations per second are displayed. If this argument is
used, the minimum threshold value must be specified using the
value
argument.
bw
Specifies that statistics for bandwidth in bytes per second are displayed. If this
argument is used, the minimum threshold value must be specified using the
value argument.
Zobrazit stránku 640