Seagate ST3400071FC Uživatelská příručka Strana 314

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 718
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 313
20.4
Command Line Interface Reference InForm OS Version 2.2.4
RESTRICTIONS
None.
EXAMPLES
The following example displays the commencement of Fibre Channel hot-plugging for drive
cage
cage0:
NOTES
Issuing the servicecage command results in chunklet relocation that causes a dip in
throughput.
The unstartfc subcommand is provided if a mistake was made when issuing the
servicecage command. The unstartfc subcommand stops the original command.
After issuing the startfc or unstartfc subcommands, the endfc subcommand must be
issued to indicate that service is completed and to restore the drive cage to its normal state.
cli% servicecage startfc –f -ovrd cage0
Zobrazit stránku 313
1 2 ... 309 310 311 312 313 314 315 316 317 318 319 ... 717 718

Komentáře k této Příručce

Žádné komentáře