Strany 1 - Dell Compellent HP-UX

Dell Compellent HP-UX Best Practices 11i v2 and 11i v1 Best Practices, Tips and Tricks

Strany 2 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|10Compellent Storage Center controller, LUNs are also mapped across t

Strany 3 - Contents

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|11Setup and Configuration HP-UX 11i v2 and v1 with Controller Failov

Strany 4

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|12Local N_Port_id is = 0xe90600 N_Port Node World Wide Name = 0x50060

Strany 5 - Document Revision

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|13presented from the Dell Compellent Storage Center to the host, as s

Strany 6 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|14would correlate the “Hardware path:” of the LUN to its respective “

Strany 7 - Preface

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|15b. It is good to note at this juncture the difference between the

Strany 8 - Introduction

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|16VGDA 2 PE Size (Mbytes) 16 Tota

Strany 9 - Best Practices

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|17 /dev/dsk/c29t0d0 /dev/rdsk/c29

Strany 10 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|18To confirm that the alternate additional path to the LUN has been a

Strany 11 - Setup and Configuration

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|19Logical volume "/dev/vgdemo/lvol1" has been successfully

Strany 12 - LUN Discovery

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|2 © 2012 Dell Inc. All rights reserved. Reproducti

Strany 13 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|20Now issue the following command to mount this new filesystem. Type:

Strany 14 - Creating a new Volume Group

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|21Dynamic LUN Expansion (DLE) and Dynamic LUN Contraction (DLC) This

Strany 15 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|22geometry of /dev/rdsk/c27t0d0: nhead=8 nsect=263 ncyl=49837 sectsz=

Strany 16 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|23mode. In any production environment, this would also require the ne

Strany 17 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|24From this output above, we would want to identify the most optimize

Strany 18 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|25"/dev/rdsk/c27t0d1" size changed from 31457280 to 5242880

Strany 19 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|26Dynamic LUN Contraction (DLC) and Thoughts With HP-UX 11i v2 (and t

Strany 20 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|27Data Instant Replay (Continuous Snapshots) It is often required in

Strany 21 - Expanding the LUN

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|28 PV Name /dev/dsk/c11t0d1 PV Name

Strany 22 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|29Type: vgchange –a n /dev/vgdemo Volume group "/dev/vgdemo"

Strany 23 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|3Contents General syntax ...

Strany 24 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|30 Back in the main Dell Compellent Storage Center window, you will n

Strany 25 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|31 You will notice that the replay just captured in highlighted in bl

Strany 26 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|32 In the next dialog, give the new Volume/LUN a new name. In this ca

Strany 27 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|33Mounting to the same host Prior to mapping this LUN to a host, capt

Strany 28 - Quiesce the Volume Group

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|34Since this new LUN shares the same Volume Group name and Volume Gro

Strany 29 - Capturing the Snapshot

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|35Type: bdf Filesystem kbytes used avail %used Mounted

Strany 30 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|36/dev/vg00/lvol6 4194304 20928 4140776 1% /tmp /dev/vg00/lvo

Strany 31 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|37 In the next dialog, read the Disclaimer then left-Click the “Conti

Strany 32 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|38 In the next dialog, give your Consistent Replay profile a name (in

Strany 33 - Mounting to the same host

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|39 In this next dialog, left-Click the “Yes” button to create this Re

Strany 34 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|4Dynamic Root Disk ...

Strany 35 - Mounting to a alternate host

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|40 In this dialog, left-Click the “Apply to Volume(s)” button. This p

Strany 36 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|41

Strany 37 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|42 Finally in this last dialog, left-Click the “Apply Now” button to

Strany 38 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|43 If importing to the same host, the vgchgid command needs to be app

Strany 39 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|44host). The import of this Volume Group would then conclude with the

Strany 40 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|45Thin Provisioning The concept of Thin Provisioning (and space recla

Strany 41 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|46Tuning for Performance In order to achieve optimized I/O with any O

Strany 42 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|47Dynamic Root Disk The HP-UX DRD (Dynamic Root Disk) toolset is made

Strany 43 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|48(Where the multiplication of the two values in RED would give you t

Strany 44 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|49configuration snapshot of the system or as a backup copy of your vg

Strany 45 - Thin Provisioning

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|5General syntax Table 1. Conventions Item Convention Menu items, dia

Strany 46 - Tuning for Performance

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|50/dev/drd00/lvol8 6029312 2200760 3798680 37% /var/opt/drd/mnts/

Strany 47 - Dynamic Root Disk

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|51 In this Advanced configuration dialog, you want to mark the checkb

Strany 48 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|52 Finally, you would left-Click the “Create Now” button to map this

Strany 49 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|53 With this new bootable LUN mapped, you would now proceed to identi

Strany 50 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|54 /dev/dsk/c3t0d2s1 /dev/dsk/c3t0d2s

Strany 51 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|55Boot from SAN (OS Boot Volume) To boot from SAN, you would need to

Strany 52 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|56iSCSI and HP-UX iSCSI is an Internet Protocol (IP)-based storage ne

Strany 53 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|57Radius Server Hostname : Header Digest : None,CRC32C

Strany 54 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|58Type: /opt/iscsi/bin/iscsiutil –a –I 172.16.26.180 Target address &

Strany 55 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|59ext_bus 45 255/0/3.0 iscsial CLAIMED INTERFACE iSCSI-SCS

Strany 56 - Assumptions

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|6Icons Notes are used to convey special information or instructions.

Strany 57 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|60Type: insf -e Finally, we issue this command and observe that all L

Strany 58 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|61 Total PE 12797 Free PE

Strany 59 - Adding LUNs

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|62CompCU (Dell Compellent Command Utility) Dell Compellent has availa

Strany 60 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|63Multiple versions of java can be loaded on an HP-UX server without

Strany 61 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|64--------------------------------------------- 11 Apache

Strany 62 - Setup and Validation

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|65 Successfully finished running Compellent Command Utility (CompCU)

Strany 63 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|66Example 3: Capturing a Volume Replay CompCU can also be used to cre

Strany 64 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|67FAQ

Strany 65 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|7Preface Audience and Assumptions  The audience is assumed to be ju

Strany 66 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|8Introduction This document presents useful information on a wide var

Strany 67 - Page

Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1 Page|9Best Practices Best practices in enterprise environments dictate the