Page | 32
J2
jumper
installation Jumper function description
Forces drive to use single-ended I/O drivers/receivers only.
Drive can operate on the interface in low voltage differential mode or
single-ended, depending on the voltage state of the I/O “DIFFSNS” line.
Default is SE jumper not installed.
Spindle starts immediately after power up - Default setting.
Drive spindle does not start until Start Unit command received from
host.
Spindle Startup is delayed by SCSI ID times 12 seconds after power is
applied, i.e., drive 0 spindle starts immediately when DC power
connected, drive 1 starts after 12 second delay, drive 2 starts after 24
second delay, etc.
Drive spindle starts when Start Unit command received from host.
Delayed start feature is overridden and does not apply when ME jumper
is installed.
Entire drive is write protected.
Drive is not write protected. Default is WP jumper not installed.
Parity checking and parity error reporting by the drive is disabled.
Drive checks for parity and reports result of parity checking to host.
Default is PD jumper not installed.
Reserved jumper position. Default is no RES jumper installed.
The drive does not supply terminator power to external terminators or to
the SCSI bus I/O cable.
Drive supplies power to SCSI bus I/O cable. When drives have differential
I/O circuits, a jumper on the TP position may be needed to power
external terminators (see system documentation).
These drives do not have terminator circuits on the drive.
Note. J2 does not exist on LC models and is supported on LW models only.