Release Notes 15
4. In the terminal emulator, connect to controller A.
5. Press Enter to display the CLI prompt (#).
6. At the prompt, type the following command to list the current settings:
7. At the prompt, type the following command to set the values you recorded for each
Ethernet management port, first for controller A and then for controller B:
where:
address is the IP address of the controller
netmask is the subnet mask
gateway is the IP address of the subnet router
a|b specifies the controller whose network parameters you are setting
For example:
8. Type the following command to verify the new IP addresses:
9. In the host computer's command window, type the following command to verify
Ethernet connectivity, first for controller A and then for controller B:
show network-parameters
set network-parameters ip address netmask netmask gateway gateway
controller a|b
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0
gateway 192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0
gateway 192.168.0.1 controller b
show network-parameters
ping IP-address