4.2 LIMIT
Frequency Class A Class B
MHz
Distance
(Meter)
Limit
dBµV/m
Distance
(Meter)
Limit
dBµV/m
30 ~ 230 10 40 10 30
230 ~ 1000 10 47 10 37
Above 1000 10 49.5 10 43.5
Remark: In the above table, the tighter limit applies at the band edges
4.3 TEST PROCEDURE
The EUT and its simulators are placed on turn table, non-conductive and wooden table,
which is 0.8 meter above ground. The turn table rotates 360 degree to determine the position
of the maximum emission level. The EUT was positioned such that distance from antenna to
the EUT is 10 meters.
The antenna is moved up and down between 1 meter to 4 meter to receive the maximum
emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order
to find the maximum emission, all of the interference cables must be manipulated according
to CISPR regulation: the test procedure of the radiated emission measurement.
The bandwidth set on the field strength is 120 KHz when the frequency range is below
1GHz
4.4 TEST SPECIFICATION
ANSI C63.4 – 2003 Section 5.2, 7.1, 7.2 & CISPR 22 - 2005
4.5 RESULT: PASSED
The radiated mission test was passed at minimum margin :
Vertical 229.45
MHz/ 37.93 dBuV/m, Antenna Height 1.74 Meter,
Turn Table 214
degree,
4.6 TEST DATA:
Please refer to appendix 2